2 Zone Fire Alarm Control Panel AW-CFP2166-2

The AW-CFP2166 series 2 Zone conventional fire alarm panel is designed based on EN54 part 2&4 standard.

Product Price
Rp1 Rp1
Quantity

  • The AW-CFP2166 series 2 Zone conventional fire alarm panel is designed based on EN54 part 2&4 standard. And it is the central part of conventional fire alarm system, designed for applications requiring smoke detector, bell, manual pull stations, and sprinkler supervision. Each zone can be disabled by a button. The basic unit offers 1 to 8 zones of initiation, up to 16 zones for larger applications.

  • 2 Zone Fire Alarm Control Panel Features
    1.Maximum number of Analogue Conventional Detector Inputs: 20 detectors each  zone
    2.Available Options: 2-4 Zone and 6-8 Zone
    3.outputs for Alarm devices: Includes 2 bells/fire relay/ fault relay
    4.Auxiliary resettable power output: 24VDC/ 100mA limiting protection
    5.Automatic power switchover: mains power and secondary power (from batteries)
    6.Independent functional buttons with indication: User friendly interface for easy operation and recognition
    7.Access levels to enter the panel
    8.Fault supervision and notification: inputs, outputs, system, power, earth, fuse
    9.Disablement: zones disablement 10.Evacuation: Fire drills to simulate fire alarm condition on panel
    11.Silence: sounders and buzzer silence 12.Walk test: indicators check

AC INPUT 
220VAC 50/60Hz
+10%
  -15%
DC OUTPUT24VDC typical
Voltage for MCU5V for MCU
Current at 24VDC from PSE450mA standby current
Maximum current from PSE1A except batteries charge
Batteries current1.85A maximum, current limited
 
Auxiliary output
24VDC +/- 10%, 100 mA max,
current limited, monitored
 
Batteries
2*12V/ 2.3Ah sealed lead acid gel,
self-regulated *
Battery low-voltage protection21V
Detectors connection allowed each zone20 (except MCPs)
Zone alarm current6mA minimum/ 27mA maximum
Sounder output2*0.75A maximum
Fire Relay1A/30VDC maximum
Fault Relay1A/30VDC    maximum
Communication protocol2 wires RS485 bus system
EOL resistor for zone6.8K 1W
EOL resistor for outputs6.8K 1W
Fuse for AC Power1 A/ 250V glass tube fuse 5 X 20mm
Fuse on DC Power1A/ 250V glass tube fuse 5 X 20mm
 
Environmental
Class A temperature range: -5 to 40°C (23~104°F)
Humidity: 5 to 95% RH, non-condensing
 
Terminal blocks rating
All terminals rated for 12 to18 AWG
(0.75 to 2.5 mm2)